X-ray Fluorescence Equipment for Gold Metal Testing

    Origin: China
    Origin: China
    X-Ray Fluorescence Equipment For Gold Metal Testing
    Product Description:
    This Test Equipment has advantages of triple radiation protection system, humanized operation interface; comprehensive application of empirical coefficient method & fundamental parameter method V8.0 analysis software. Element measuring range is from Na to U, which can test Pb, Cd, Hg and PBB in the RoHS regulations; Br in PBDE; Cr in Cr6+; Cl and Br in the Halogen-free regulations. It can completely meet the control demand of RoHS/WEEE/Halogen-free. Our machine with spectrum comparison function is used for real time tracing material change and warning in time. It has the incomparable advantage for RoHS/Halogen-free control.

    Application

    RoHS Directive Control Products: Household Appliance/ Information Technology and Communications Equipment / Electric Tool /Toys and other equipment.
    Halogen-free Directive Control Products: Products which use flame retardant containing Cl, Br and other elements as raw material.


    Standard Features
    Item Description
    Sample cavity size 300*300*80mm
    Element measuring range S-U
    Measuring range 1ppm-99.99%
    RoHS test limit Pb≤5ppm,Cd/Cr/Hg/Br≤2ppm,Cl≤50ppm
    Sample type solid, powder and liquid
    Measuring time 120-400s ( software auto adjustment )
    Collimator Φ2mm,Φ5mm
    Filter 8 type composite filter switch automatically
    CCD observation 1.30 Million pixel HD CCD
    Sample micro scope XY8mm
    Stability Repeatability error<0.1% for multi-measurement
    Input power AC220V~240V,50/60Hz
    Rated power 350W
    Weight Approx 48Kg
    Instrument size 640(W)x450(D)x412(H)mm

    Instrument Features
    1.  Triple radiation protection system (software, hardware, Labyrinth design) protect operator from radiation harm;
    2.  Adapting new design with optical path, which maximally solves negative effect of air optical path for Cl element measurement to guarantee Cl element stability;
    3.  The new optimized V8.0 analysis software can auto set the ray tube power according to the sample material, shape and size. It can prolong the life time of ray tube and also fully play detector's function and increase measurement precision greatly;
    4.  Combined with series of advanced spectrum processing method including FFT, precise background deductive method, automatic peak search and Quasi-Newton optimize calculation etc;
    5.  International advanced XRF analysis software which combines with several traditional analysis method such as empirical coefficient method and the fundamental parameter method (FP method),  theoretical α coefficient method and so on, guarantees the precision of measuring data;
    6.  Software can issue report by format Excel, PDF;
     
    Detector system
    X-ray Fluorescence Equipment for Gold Metal Testing
     
    Brand: AMPTEK
    Be window thickness: 1mil (0.0254mm)
    Best resolution rate: 145±5eV
    System peak to background ratio: ≥ 6200/1
    Energy response range: 1keV ~ 40keV
    Recommend counting rate: 5000cps
    X ray tube
    X-ray Fluorescence Equipment for Gold Metal Testing

     
    Voltage: 0 ~ 50 kV
    Max. current: 1.0 mA
    Max. power: 50 W
    Filament voltage: 2.0V
    Filament current: 1.7 A
    Radiation out degree: 12°
    Target material: Mo
    Be window thickness: 400um
    High voltage power supply  
    X-ray Fluorescence Equipment for Gold Metal Testing
     
    Input voltage: DC +24V±10%
    Input current: 4.25A (max)
    Output voltage: 0 -50KV & 1mA
    Max power: 50W
    Voltage regulation: 0.01% (From no load to full load)
    Current regulation: 0.01% (From no load to full load)
    Ripple ratio: Prior to the stable output voltage, ripple voltage
    peak value is 0.25% of the highest output voltage.
    8 hours stability: ≤0.05%
    Test platform
    X-ray Fluorescence Equipment for Gold Metal Testing
     
    Test platform with fine-tuning device external of the instrument, combine with 1.3 million pixel HD CCD, which can easily position sample accurately to avoid inaccurate result.
    High resolution CCD
    X-ray Fluorescence Equipment for Gold Metal Testing
     
    1.3 million pixel HD CCD camera can be able to observe the measuring area real time and take pictures for test report.
    Cooling system
    X-ray Fluorescence Equipment for Gold Metal Testing
     
    High efficiency 3D cooling system improves the reliability and stability of instruments greatly.

    Our company Introduction:
    HAIDA INTERNATIONAL is a professional manufacturer of various kinds of testing equipments over 24 years. HAIDA products are widely used in paper products, packaging, ink printing, adhesive tapes, bags, footwear, leather products, environment, toys, baby products, hardware, electronic products, plastic products, rubber products and other industries, and applicable to all scientific research units, quality inspection institutions and academic fields.

    After-service:

    If you face any problems in future during testing process we promise we will give you a reply within 48 hours and solution provide within 3 working days. We can offer operation video and English operation muanual. We can provide video-con.
    X-Ray Fluorescence Equipment For Gold Metal Testing
    Product Description:
    This Test Equipment has advantages of triple radiation protection system, humanized operation interface; comprehensive application of empirical coefficient method & fundamental parameter method V8.0 analysis software. Element measuring range is from Na to U, which can test Pb, Cd, Hg and PBB in the RoHS regulations; Br in PBDE; Cr in Cr6+; Cl and Br in the Halogen-free regulations. It can completely meet the control demand of RoHS/WEEE/Halogen-free. Our machine with spectrum comparison function is used for real time tracing material change and warning in time. It has the incomparable advantage for RoHS/Halogen-free control.

    Application

    RoHS Directive Control Products: Household Appliance/ Information Technology and Communications Equipment / Electric Tool /Toys and other equipment.
    Halogen-free Directive Control Products: Products which use flame retardant containing Cl, Br and other elements as raw material.


    Standard Features
    Item Description
    Sample cavity size 300*300*80mm
    Element measuring range S-U
    Measuring range 1ppm-99.99%
    RoHS test limit Pb≤5ppm,Cd/Cr/Hg/Br≤2ppm,Cl≤50ppm
    Sample type solid, powder and liquid
    Measuring time 120-400s ( software auto adjustment )
    Collimator Φ2mm,Φ5mm
    Filter 8 type composite filter switch automatically
    CCD observation 1.30 Million pixel HD CCD
    Sample micro scope XY8mm
    Stability Repeatability error<0.1% for multi-measurement
    Input power AC220V~240V,50/60Hz
    Rated power 350W
    Weight Approx 48Kg
    Instrument size 640(W)x450(D)x412(H)mm

    Instrument Features
    1.  Triple radiation protection system (software, hardware, Labyrinth design) protect operator from radiation harm;
    2.  Adapting new design with optical path, which maximally solves negative effect of air optical path for Cl element measurement to guarantee Cl element stability;
    3.  The new optimized V8.0 analysis software can auto set the ray tube power according to the sample material, shape and size. It can prolong the life time of ray tube and also fully play detector's function and increase measurement precision greatly;
    4.  Combined with series of advanced spectrum processing method including FFT, precise background deductive method, automatic peak search and Quasi-Newton optimize calculation etc;
    5.  International advanced XRF analysis software which combines with several traditional analysis method such as empirical coefficient method and the fundamental parameter method (FP method),  theoretical α coefficient method and so on, guarantees the precision of measuring data;
    6.  Software can issue report by format Excel, PDF;
     
    Detector system
    X-ray Fluorescence Equipment for Gold Metal Testing
     
    Brand: AMPTEK
    Be window thickness: 1mil (0.0254mm)
    Best resolution rate: 145±5eV
    System peak to background ratio: ≥ 6200/1
    Energy response range: 1keV ~ 40keV
    Recommend counting rate: 5000cps
    X ray tube
    X-ray Fluorescence Equipment for Gold Metal Testing

     
    Voltage: 0 ~ 50 kV
    Max. current: 1.0 mA
    Max. power: 50 W
    Filament voltage: 2.0V
    Filament current: 1.7 A
    Radiation out degree: 12°
    Target material: Mo
    Be window thickness: 400um
    High voltage power supply  
    X-ray Fluorescence Equipment for Gold Metal Testing
     
    Input voltage: DC +24V±10%
    Input current: 4.25A (max)
    Output voltage: 0 -50KV & 1mA
    Max power: 50W
    Voltage regulation: 0.01% (From no load to full load)
    Current regulation: 0.01% (From no load to full load)
    Ripple ratio: Prior to the stable output voltage, ripple voltage
    peak value is 0.25% of the highest output voltage.
    8 hours stability: ≤0.05%
    Test platform
    X-ray Fluorescence Equipment for Gold Metal Testing
     
    Test platform with fine-tuning device external of the instrument, combine with 1.3 million pixel HD CCD, which can easily position sample accurately to avoid inaccurate result.
    High resolution CCD
    X-ray Fluorescence Equipment for Gold Metal Testing
     
    1.3 million pixel HD CCD camera can be able to observe the measuring area real time and take pictures for test report.
    Cooling system
    X-ray Fluorescence Equipment for Gold Metal Testing
     
    High efficiency 3D cooling system improves the reliability and stability of instruments greatly.

    Our company Introduction:
    HAIDA INTERNATIONAL is a professional manufacturer of various kinds of testing equipments over 24 years. HAIDA products are widely used in paper products, packaging, ink printing, adhesive tapes, bags, footwear, leather products, environment, toys, baby products, hardware, electronic products, plastic products, rubber products and other industries, and applicable to all scientific research units, quality inspection institutions and academic fields.

    After-service:

    If you face any problems in future during testing process we promise we will give you a reply within 48 hours and solution provide within 3 working days. We can offer operation video and English operation muanual. We can provide video-con.

    Previous Post: China Manufacturer High Energy Efficiency Cube Ice Maker Machine for Bar
    Next Post: Poultry Whole Chicken Dynamic Weighing and Sorting Machine
    Home
    Recent Posts
    • Newzealand Gantry Bins No Door
    • Med-L-Yqx-T Anaerobic Incubator Lab Incubator
    • Chrome Plated Handle Stop Valve as-Ws004
    • Single PE Coated Paper Cup Machine for Hot Drink…
    • Jy-16A Blood Micro Hematocrit Centrifuge
    • Student Optical Binocular Biological Microscope …
    • Micropette Multi-Channel Pipette
    • Auto Agriculture Water Meter Residual Chlorine C…
    • 1600X Biological Microscope with CE Approved Yj-…
    • 11mm Crimp Top HPLC Glass Vials
    • Eight-Channel Adjustable Volume Mechanical Autoc…
    • Light Weight Dispensing Strong Universality Pipe…
    • Medical Supply Prepared Microscope Slides
    • Chrome Plated Zinc Alloy Handle Stop Valve as-Ws…
    • Single Channel Suction Pipette Uses in Laborator…
    • Economy Urine Bag with Twist Turn Valve Injectio…
    • Paper Cup Intelligent Production Line
    • Centrifuge Spun Machine for Concrete Poles
    • Low Price Pet Incinerator Medical Waste Incinera…
    • SX-B4 400x Student Biological Microscope