Solenoid valve does not move the exclusion method

    Solenoid valve failure will have a direct impact on the switching valve and control valve action, switching valve solenoid valve failure, should choose the appropriate time, so the solenoid valve is in the loss of power for processing. If you can not finish processing within a switching gap, you can pause the switching system and handle it gracefully. Solenoid valve does not move the method of troubleshooting Common faults solenoid valve does not move, should be investigated from the following aspects: (1) leak. Leakage will result in insufficient air pressure, making it difficult to open and close the forced valve due to damaged gaskets or slide valve wear caused by several cavity blow-by gas. (2) Solenoid valve lug loose or thread off, the solenoid valve can not be electric, can tighten the thread. (3) solenoid valve stuck. Solenoid valve sleeve and valve spool with a very small gap (less than 0.008mm), are generally a single assembly, when mechanical impurities into or too little oil, it is easy to get stuck. Approach can be used steel wire from the hole into the head, make it bounce. The fundamental solution is to remove the solenoid valve, remove the valve plug and spool sleeve, with CCI4 cleaning, making the spool movement in the valve sleeve flexibility. Disassembly should pay attention to the assembly sequence and the location of external wiring in order to reassemble and wiring properly, but also check the oil mist hole is blocked, the lubricating oil is sufficient. Solenoid valve does not move the exclusion method (4) Solenoid coil burned out, remove the solenoid valve wiring, with a multimeter to measure, if the open circuit, the solenoid valve coil burned out. The reason is the coil damp, resulting in poor insulation and leakage flux, causing the coil current is too large and burned, so to prevent rain into the solenoid valve. In addition, the spring is too strong, the reaction force is too large, the number of coil turns is too small, and the suction is insufficient, the coil can also be burned. In emergency, the manual button on the coil can be turned to "1" position by the "0" bit during normal operation, so that the valve is opened.

    Gasket Plate Heat Exchangerbrazed

    Nantong Tobel Intelligent Controlling Equipment CO;LTD , https://www.tobel-tech.com

    Previous Post: 711 is responsible for the cutter suction dredging ship technology research project
    Next Post: The development of the machine tool industry faces the survival of the fittest
    Home
    Recent Posts
    • The profit rate of autonomous auto makers is not…
    • Numerical Control Machine (Milling Machine) All …
    • Enhancing the core technology of pump valves bec…
    • XCMG dump truck opens up new markets in Southeas…
    • Omak CNC Machine Tool Interview
    • An interview with BMW Beijing Yingzhibao product…
    • Development Status and Opportunities of China…
    • Ministry of Commerce Finalizes Polysilicon Doubl…
    • 711 is responsible for the cutter suction dredgi…
    • Solenoid valve does not move the exclusion metho…
    • The development of the machine tool industry fac…
    • STX Dalian successfully developed 7K98ME host
    • FD830A Rotary Drilling Rig Hits New Year's F…
    • FD830A Rotary Drilling Rig Hits New Year's F…
    • Traffic resources should be allocated according …
    • Henan Pinggao all closed composite electrical su…
    • 2012 auto parts exports fall into sluggish growt…
    • Constant temperature and humidity failure, how t…
    • Government accelerates elimination of low-end co…
    • Huntington-Ingles wins $9.3 million naval valve …