Water Cooling Type Stable Laser Length800mm Dia50mm Min 40W Max 45W CO2 Laser Glass Tube

    Model NO.: BL-800 40-45W CO2 laser tube
    Laser Classification: Gaseous Laser
    Engraving Method: Lattice Engraving
    Length: 800mm
    Diameter: 50mm
    Cooling Method: Water
    Warranty: 3months
    Service Life: 3000hours
    Min Laser Power: 40W
    Max Laser Power: 45W
    Usage: 40W CO2 Laser Engraving Machine
    Material: Glass
    Delivery Time: 5-7 Working Days for 50PCS
    Trademark: Rubylasertech
    Transport Package: Wooden Box and Foam
    Specification: 800mm length 50mm diameter 40-45W CO2 laser tube
    Origin: Jinan China
    HS Code: 9013220009
    Model NO.: BL-800 40-45W CO2 laser tube
    Laser Classification: Gaseous Laser
    Engraving Method: Lattice Engraving
    Length: 800mm
    Diameter: 50mm
    Cooling Method: Water
    Warranty: 3months
    Service Life: 3000hours
    Min Laser Power: 40W
    Max Laser Power: 45W
    Usage: 40W CO2 Laser Engraving Machine
    Material: Glass
    Delivery Time: 5-7 Working Days for 50PCS
    Trademark: Rubylasertech
    Transport Package: Wooden Box and Foam
    Specification: 800mm length 50mm diameter 40-45W CO2 laser tube
    Origin: Jinan China
    HS Code: 9013220009
    40W-50W CO2 Laser Tube

    1.Feature:

    This series CO2 laser tube is matured product. It has high cost performance and stable performance. It has been adopted by many factories for medical equipment and CO2 laser stamping machines. Also these tubes are exported to other countries with laser machines. The excellent laser spot and stable laser power make the laser tube distinguished and high praised.
    This series CO2 laser tube's power stability is not more than ±5%.It is widely used at medical equipment and laser carving or engraving machine.
     
    2.Specification
    Model Length
    (mm)
    Diameter
    (mm)
     
    Rated Power
    ( W)
    Peak Power
    ( W)
    Work Current
    (mA)
    Working life
    ( Hours)
    Warranty
    (Month)
    BL-450 450 50 18 25 12 2500-3000 3
    BL-600 600 50 25 35 15 2500-3000 3
    BL-700 700 50 35 40 15 2500-3000 3
    BL-800 800 50 40 45 18 2500-3000 3
    BL-850 850 50 40 45 18 2500-3000 3
    BL-950 950 50 40 50 20 2500-3000 3
    BL-1000 1000 50 40 50 20 2500-3000 3

    Note
    CO2 laser tube warranty:3 months.
    Delivery time:2 working days after payment received.
    Package:Carton,foam and wooden box.
    Shipping method:DHL,UPS,Fedex or TNT
    Payment method: T/T,PAYPAL,Western Union
    Application:General type laser tube and widely used on 40-50watt CO2 laser engraving or stapm machine

    Water Cooling Type Stable Laser Length800mm Dia50mm Min 40W Max 45W CO2 Laser Glass Tube
    Water Cooling Type Stable Laser Length800mm Dia50mm Min 40W Max 45W CO2 Laser Glass Tube
    Water Cooling Type Stable Laser Length800mm Dia50mm Min 40W Max 45W CO2 Laser Glass Tube
    Water Cooling Type Stable Laser Length800mm Dia50mm Min 40W Max 45W CO2 Laser Glass Tube

    Common problem on CO2 laser tube
     
    1 .CO2 tube's power is low and power's falling speed is fast.
    A.  Check if working current exceeds permitted current's 10%. If it is long time at this situation, tube's power will fall very fast. Please check if the CO2 power supply is matched with this tube and input voltage is normal.
     B.  Check if water cooling system is normal. It contains cooling water's  temperature, water flow volume and water's quality. During working, water's temperature should not be large than 30
    ºC and  water flow volume is not more than 4L/min(This data can be increased according to different model CO2 tube). Cooling water should be changed frequently and must be clean.
     C.  Check CO2 tube's output lens ,reflective mirror and focus lens is dirty. Also check if laser optics is correct. Because mirror or lens is easy dirty during optics adjustment.  If so, please use 99.7% absolute alcohol clear them.
    D.  Check if discharge diode's color is normal. If it is blue or purple or shows white color, it is not good condition.
     
    2. Bad laser spot or laser spot changes
    Check if cooling water is normal.
    Check if working current is too large.
    Check if installation direction is correct.
    Check if bracket is correct. Generally it is at CO2 tube's 1/4 position.
    Check if lens or mirror is dirty or be sheltered.
    Check if discharge color is normal. If CO2 gas leaked, laser spot also is effected.
     
    3 .CO2 laser tube doesn't output laser
    Check if CO2 power supply's control wires are connected correctly then check if connection wring between CO2 tube and CO2 power supply are correctly.
    Pull out all signal terminal and connect power supply and laser tube correctly, then press TEST button(Red) at front side of power supply.
     
    Check if discharge diode's color is normal and check if it has ignition sparks.  If tube is not damaged and ignition discharge is blue or purple, it indicates CO2 gas leak. If no ignition discharge and it has high voltage discharge sound when press TEST (Red) button at power supply, it also indicates CO2 gas leak.
    If ignition discharge is white and no laser output, it indicates working gas is resolved.
    If it has bright white spot when press TEST (Red)button at power supply or it has wave discharge when ignition, it indicates high voltage breakdown.  Please check if cooling water system or working current is normal.  Or check if power supply is matched with CO2 laser tube.
    Check if it has water in side of CO2 tube and inner tube is damaged.
     
    4 .CO2 laser tube burst or damaged
    If it has circular arc and smooth burst at near 10cm of glass connection, it is caused by stress.
     If it has serrated and wave burst at near negative electrode slice and serious damage with many fragments, it is caused by cooling water.
    If electrode's terminal or cooling water box is damaged slightly and inner lens is good, it can be repaired. The electrode terminals and cooling water box are treated by high temperature. If it is not outside force,generally they are not easy be damaged
     
    5 .Not good engraving
    Check if CO2 laser tube and power supply is matched with each other. If it has tailing or non smooth shading, it is caused by this reason.
    Connect or disconnect connection metal wire between negative electrode terminal and metal cooling water box.
    Check if it has correct laser early output parameter setting.
     
    6 .Not good cutting
    Check if cooling water system is normal.
    Check if focus length is correct
    Adjust air blowing amount.
    Change software's image(round or squre) and then make cutting. This way is used to figure if it is image's problem.


      40W-50W CO2 Laser Tube

    1.Feature:

    This series CO2 laser tube is matured product. It has high cost performance and stable performance. It has been adopted by many factories for medical equipment and CO2 laser stamping machines. Also these tubes are exported to other countries with laser machines. The excellent laser spot and stable laser power make the laser tube distinguished and high praised.
    This series CO2 laser tube's power stability is not more than ±5%.It is widely used at medical equipment and laser carving or engraving machine.
     
    2.Specification
    Model Length
    (mm)
    Diameter
    (mm)
     
    Rated Power
    ( W)
    Peak Power
    ( W)
    Work Current
    (mA)
    Working life
    ( Hours)
    Warranty
    (Month)
    BL-450 450 50 18 25 12 2500-3000 3
    BL-600 600 50 25 35 15 2500-3000 3
    BL-700 700 50 35 40 15 2500-3000 3
    BL-800 800 50 40 45 18 2500-3000 3
    BL-850 850 50 40 45 18 2500-3000 3
    BL-950 950 50 40 50 20 2500-3000 3
    BL-1000 1000 50 40 50 20 2500-3000 3

    Note
    CO2 laser tube warranty:3 months.
    Delivery time:2 working days after payment received.
    Package:Carton,foam and wooden box.
    Shipping method:DHL,UPS,Fedex or TNT
    Payment method: T/T,PAYPAL,Western Union
    Application:General type laser tube and widely used on 40-50watt CO2 laser engraving or stapm machine

    Water Cooling Type Stable Laser Length800mm Dia50mm Min 40W Max 45W CO2 Laser Glass Tube
    Water Cooling Type Stable Laser Length800mm Dia50mm Min 40W Max 45W CO2 Laser Glass Tube
    Water Cooling Type Stable Laser Length800mm Dia50mm Min 40W Max 45W CO2 Laser Glass Tube
    Water Cooling Type Stable Laser Length800mm Dia50mm Min 40W Max 45W CO2 Laser Glass Tube

    Common problem on CO2 laser tube
     
    1 .CO2 tube's power is low and power's falling speed is fast.
    A.  Check if working current exceeds permitted current's 10%. If it is long time at this situation, tube's power will fall very fast. Please check if the CO2 power supply is matched with this tube and input voltage is normal.
     B.  Check if water cooling system is normal. It contains cooling water's  temperature, water flow volume and water's quality. During working, water's temperature should not be large than 30
    ºC and  water flow volume is not more than 4L/min(This data can be increased according to different model CO2 tube). Cooling water should be changed frequently and must be clean.
     C.  Check CO2 tube's output lens ,reflective mirror and focus lens is dirty. Also check if laser optics is correct. Because mirror or lens is easy dirty during optics adjustment.  If so, please use 99.7% absolute alcohol clear them.
    D.  Check if discharge diode's color is normal. If it is blue or purple or shows white color, it is not good condition.
     
    2. Bad laser spot or laser spot changes
    Check if cooling water is normal.
    Check if working current is too large.
    Check if installation direction is correct.
    Check if bracket is correct. Generally it is at CO2 tube's 1/4 position.
    Check if lens or mirror is dirty or be sheltered.
    Check if discharge color is normal. If CO2 gas leaked, laser spot also is effected.
     
    3 .CO2 laser tube doesn't output laser
    Check if CO2 power supply's control wires are connected correctly then check if connection wring between CO2 tube and CO2 power supply are correctly.
    Pull out all signal terminal and connect power supply and laser tube correctly, then press TEST button(Red) at front side of power supply.
     
    Check if discharge diode's color is normal and check if it has ignition sparks.  If tube is not damaged and ignition discharge is blue or purple, it indicates CO2 gas leak. If no ignition discharge and it has high voltage discharge sound when press TEST (Red) button at power supply, it also indicates CO2 gas leak.
    If ignition discharge is white and no laser output, it indicates working gas is resolved.
    If it has bright white spot when press TEST (Red)button at power supply or it has wave discharge when ignition, it indicates high voltage breakdown.  Please check if cooling water system or working current is normal.  Or check if power supply is matched with CO2 laser tube.
    Check if it has water in side of CO2 tube and inner tube is damaged.
     
    4 .CO2 laser tube burst or damaged
    If it has circular arc and smooth burst at near 10cm of glass connection, it is caused by stress.
     If it has serrated and wave burst at near negative electrode slice and serious damage with many fragments, it is caused by cooling water.
    If electrode's terminal or cooling water box is damaged slightly and inner lens is good, it can be repaired. The electrode terminals and cooling water box are treated by high temperature. If it is not outside force,generally they are not easy be damaged
     
    5 .Not good engraving
    Check if CO2 laser tube and power supply is matched with each other. If it has tailing or non smooth shading, it is caused by this reason.
    Connect or disconnect connection metal wire between negative electrode terminal and metal cooling water box.
    Check if it has correct laser early output parameter setting.
     
    6 .Not good cutting
    Check if cooling water system is normal.
    Check if focus length is correct
    Adjust air blowing amount.
    Change software's image(round or squre) and then make cutting. This way is used to figure if it is image's problem.


     

    Folding Clothes Machine

    Folding Machine For Clothes

    Machine Folding Clothes

    Clothes Folding Machine

    Clothes Packaging Machine

    Clothes labeling machine

    Folding Clothes Machine,folding machine for clothes,machine folding clothes,clothes folding machine

    SHENZHEN LINGCHUANG ZHUOYUE TECHNOLOGY CO., LTD , https://www.szlcautos.com

    Previous Post: Suspension Roller Concrete Pipe Making Machine (XG 1200)
    Next Post: Desiccant Wheel Dehumidifier with Silica Gel Rotor
    Home
    Recent Posts
    • Tr-50 Dyneema Synthetic 4X4 Winch Rope with Hook…
    • Tr-09 Manual Hand Winch Dyneema Synthetic 4X4 Wi…
    • UHMWPE Synthetic Dyneema Fiber Winch Rope with H…
    • Zinc Brass Two Way Angle Valve
    • Plastic Soft Test Tube with Rubber Tube Cap, Inj…
    • Ministry of Industry and Information Technology:…
    • Electric hammer dust removal system introduction…
    • LED business performance is weak, Depp Technolog…
    • do you know? Purchase Taxes for Special Vehicles
    • The off-season continued to decline in February.
    • OEM Industrial Equipment Gas Strut
    • The first line-controlled boring machine was suc…
    • Vaccine cold chain truck_Disease control vaccine…
    • S&A water chiller for cooling the analytical lab…
    • 100% Quality Guarantee Butyl Rubber Motorcycle I…
    • A new type of clean raw material can be complete…
    • Use a pressure relief valve to extend the life o…
    • Chuanzhong Oil & Gas Mine Nanchong Hexun Co.…
    • Tow Cable Tow Strap Car Towing Rope with Hooks H…
    • Black Synthetic Winch Rope/Black Safety Thimble …