Power cable fault test technology

    1. Create several concepts:

    1 long-term theory: the so-called long line refers to the geometric length of the line is longer than the wavelength of the electromagnetic wave transmitted on it or can be compared with the transmission line; the other hand is short-term. No matter whether the low-voltage pulse method or the high-voltage inner-circuit method detects the fault distance of the power cable, it is a microscopic process that discusses the propagation of the electric wave in the power cable. The power cable is considered as a “uniform long line”. According to the variation law of the amplitude, phase, speed and other parameters of the electric wave in the transmission process, the radar fault distance principle is used to determine the fault point distance.

    2 Microwave transmission theory (radar principle): When an electric wave propagates in a long line, a reflection wave is inevitably generated when the characteristic impedance of the cable changes. By analyzing the time difference between the incident wave and the reflected wave, the distance of the fault point can be calculated.

    3 Reflection coefficient: It refers to the ratio of the reflected wave to the incident wave at a certain point on the long line, that is, the ratio of the voltage (or current) of the reflected wave at a certain point on the long line to the amplitude of the incident wave voltage (or current). Divided into the following situations:

    0<freverse ≤1 Normal reflection—the amplitude changes.

    When f=1, open circuit;

    -1≤f&lt;< negative reflex - both amplitude and phase change

    When f = -1, a short circuit occurs.

    2, the principle of cable fault testing

    The cable fault test is based on the reflection of the radio wave on the microwave transmission line to achieve a rough measurement of the cable fault.

    For low-resistance and open-circuit faults, the smart flicker itself generates and transmits a pulsed signal to the faulty cable. After the electrical pulse transmitted in the cable encounters the fault point or cable anomaly, a reflected pulse is returned along the original cable path back to the transmission. End, the application of distance formula S = vt available:

    S=1/2vt..................................................................1

    Where: S---- Distance from fault point to test end

    v----The transmission speed of the electrical signal in the cable is only related to the insulation medium of the cable; it is a constant regardless of the conductor material of the cable. For example, the oil-impregnated paper cable v≈160m/μs; the cross-linked polyethylene cable v≈ 170m/μs.

    T = the time required for the electrical signal to be sent from the test end to the point of failure and then back to the sender.

    Therefore, as long as the time T is measured, the distance from the fault point to the test end can be known.

    For high-impedance faults, the intelligent flicker tester uses the fault point of the cable under high voltage to form a momentary short-circuit fault by flashover discharge, and simultaneously tests the principle of the echo signal. Measure the time difference between the two echo signals. Use Equation 1 to calculate the distance from the fault point to the test end.

    API 5L Line Pipe SSAW Steel Pipe

    Certificate: EN10217, EN10219, API 5L PSL1/ PSL2, API 5CT

    Out Diameter: 168.3mm –3048mm

    Wall Thickness: 3.2mm-30mm

    Length: Up to 50m

    Steel Grade:

    API 5L: GR A, GR B, X42,X46, X56, X60,X65,X70

    ASTM A252 GR 1, GR 2, GR 3

    ASTM A53: GR A, GR B, GR C, GR D

    BS 4360: Grade 43, Grade 50

    EN: S275, S275JR, S355JRH, S355J2H

    Surface: Fusion bond Epoxy coating, Coal Tar Epoxy, 3PE, Vanish Coating, Bitumen Coating, Black Oil coating as per customer`s requirement

    Test: Chemical Component Analysis, Mechanical Properties (Ultimate tensile strength, Yield strength, Elongation), Technical Properties (Flattening Test, Bending Test, Blow Test, Impact Test), Exterior Size Inspection, Hydrostatic Test, X-ray Test.

    SSAW Steel Pipe

    Piling SSAW Steel Pipe, API 5L SSAW Steel Pipe, Big Diameter SSAW Steel Pipe, Structural SSAW Pipe

    Cangzhou Weiheng Pipe Industry Co.,Ltd , http://www.czweiheng.com

    Previous Post: Winter powder grain transport vehicle maintenance
    Next Post: Analysis of Causes of Unstable Humidification in Artificial Climate Boxes
    Home
    Recent Posts
    • Cavotec receives 10 million euro port crane matc…
    • · Three major US automakers saw their car sales…
    • What is the difference between spot welder and p…
    • There are ways to prevent the burning of gasolin…
    • How big is the new energy vehicle market? After …
    • Analysis of Natural Gas Flowmeter Category and I…
    • Analysis of common faults in the use of electrom…
    • NASA developed a new solid-state battery: the vo…
    • China has vigorously developed nearly 60,000 agr…
    • How to accurately find electronic floor scale fa…
    • Hook arm garbage truck how much money --- nation…
    • What is smart transportation? Why do you want to…
    • China National Heavy Duty Truck MC07 engine fitt…
    • Fast: Keeping a close eye on market demand
    • China's light trucks boast a pride and passi…
    • What are the common faults encountered in daily …
    • Hankook will directly acquire Australia's la…
    • Energy-saving and energy comprehensive utilizati…
    • ·112 vehicle companies passed the national new …
    • Policy dividends plus 2017 forage mechanization …