Professional Infrared Baby Adult Digital Thermometer

    Model NO.: UP-580
    Trademark: OEM
    Transport Package: OEM Packing
    Specification: 39*27.3*160mm
    Origin: China
    HS Code: 9025199010
    Model NO.: UP-580
    Trademark: OEM
    Transport Package: OEM Packing
    Specification: 39*27.3*160mm
    Origin: China
    HS Code: 9025199010
    Professional Infrared Baby Adult Digital Thermometer

    Features


     Instant reading; Quick measurement, get reading in 1 second.
     Adopt the latest algorithm with optimized temperature calibration function.

     Accurate and reliable; ±0.2ºC High accuracy.

     Smart and Intelligent; One-button easy operation.
     Tri-color indicator light, display green, orange & red with fever alarm function.
     Memory function; Memory recall of 35 reading.
     Multi function design, can measure forehead/ear, room, object temperature.
     Switching between mute and un-mute.
     Switching between Fahrenheit and Celsius.
     Automatic shutdown and power saving.
     Optional function: 1. Ear probe cover.  2. Bluetooth connection.
    Specifications

     
    Model No. FC-IR100
    Measurement range Ear & Forehead: 32.0°C-42.9°C (89.6°F-109.2°F)
    Object: 0°C-100°C (32°F-212°F)
    Measuring accuracy Ear & Forehead mode:±0.2ºC /±0.4°F
    Object mode:±1.0°C/1.8°F
    Display  LCD backlight
    Automatic shutdown 10s±1s
    Memory Memory 35 groups of measured temperature.
    Fever alarm Low fever:37.4ºC<=T<=37.9ºC°(99.3°F-100.3°F)
    High fever:38ºC<=T<=42.9ºC(100.4°F-109.2°F)
    Operational conditions Temperature: 10ºC-40ºC (50°F-104°F)
    Humidity: 15-95%RH, non-condensing

    Atmospheric pressure: 86-106 kPa
    Battery 2*AAA, can be used for more than 3000 times
    Weight 66g(without battery); 81g (with battery)
    Product Dimension 39*27.3*160mm
    Packing size 46.5*46.5*169mm
    Full set weight 113g (including products / bags / instructions/ batteries)

    4.Overview

    Infrared Thermometer measures the body temperature based on the infrared energy emitted from the eardrum or the forehead. Users can quickly get measurement results after positioning properly the temperature probe in the ear canal or forehead.

    Normal body temperature is a range. The following tables shows that this normal range also varies by site. Therefore, readings from different site should not be directly compared. Tell your doctor what type of thermometer you used to take your temperature and on what part of the body. Also bear this in mind if you are diagnosing yourself.

     

    Measurements

    Forehead temperature

    36.1°C to 37.5°C (97°F to 99.5°F)

    Ear temperature

    35.8°C to 38°C (96.4°F to 100.4°F)

    Oral temperature

    35.5°C to 37.5°C (95.9°F to 99.5°F)

    Rectal temperature

    36.6°C to 38°C (97.9°F to 100.4°F)

    Axillary temperature

    34.7°C-37.3°C (94.5°F-99.1°F)

     

    5.Structure

    The thermometer consists of a shell, an LCD, a measure button, a beeper, an infrared temperature sensor, and a Microprocessor.

    6.Operating principle

    The infrared temperature sensor collects infrared energy emitted by the eardrum or the skin surface. After being focused by a lens, the energy is converted into a temperature reading by the thermopiles and measurement circuits.

    7.Indications for use

    The Dual-mode Infrared Thermometer is intended for the measurement of human body temperatures. The forehead mode is indicated for people of all ages and the eardrum mode is indicated for people above three months old.

    8.Contraindications

    Do not use the thermometer if the ear is infected with otitis or suppuration.

    9.Temperature taking tips

    1) It is important to know each individual's normal temperature when they are well. This is the only way to accurately diagnose a fever. Record readings twice a day (early morning and late afternoon). Take the average of the two temperatures to calculate normal oral equivalent temperature. Always take the temperature in the same location, since the temperature readings may vary from different locations on the forehead.

    2) A child's normal temperature can be as high as 99.9°F (37.7) or as low as 97.0°F (36.11). Please note that this unit reads 0.5ºC (0.9°F) lower than a rectal digital thermometer.

    3) External factors may influence ear temperatures, including when an individual has:

    • been lying on one ear or the other

    • had their ears covered

    • been exposed to very hot or very cold temperatures

    • been recently swimming or bathing

    In these cases, remove the individual from the situation and wait 20 minutes prior to taking a temperature.

    Use the untreated ear if prescription ear drops or other ear medications have been placed in the ear canal.

    4) Holding the thermometer for too long in the hand before taking a measurement can cause the device to warm up. This means the measurement could be incorrect.

    5) Patients and the thermometer should stay in steady-state room condition for at least 30 minutes.

    6) Before placing the thermometer sensor onto the forehead, remove dirt, hair, or sweat from the forehead area. Wait 10 minutes after cleaning before taking measurement.

    7) Use an alcohol swab to carefully clean the sensor and wait for 5 minutes before taking a measurement on another patient. Wiping the forehead with a warm or cool cloth may impact your reading. It is advised to wait 10 minutes before taking a reading.

    8) In the following situations it is recommended that 3-5 temperatures in the same location be taken and the highest one taken as the reading:

    • Newborn infants in the first 100 days.

    • Children under three years of age with a compromised immune system and for whom the presence or absence of fever is critical.

    • When the user is learning how to use the thermometer for the first time until he/she has familiarized himself/herself with the instrument and obtains consistent readings.

    10.Care and cleaning

    Use an alcohol swab or cotton swab moistened with 70% alcohol to clean the thermometer casing and the measuring probe. After the alcohol has completely dried out, you can take a new measurement.

    Ensure that no liquid enters the interior of the thermometer. Never use abrasive cleaning agents, thinners or benzene for cleaning and never immerse the instrument in water or other cleaning liquids. Take care not to scratch the surface of the LCD screen.

    11.Warranty and After-Sale Service

    The device is under warranty for 12 months from the date of purchase.

    The batteries, the packaging, and any damage caused by improper use are not covered by the warranty.

    Excluding the following user-caused failures:

    • Failure resulting from unauthorized disassembly and modification.

    • Failure resulting from an unexpected dropping during application or transportation.

    • Failure resulting from not following the instructions in the operating manual.

    OUR FACTORY
    Professional Infrared Baby Adult Digital Thermometer

    Performance show

    Professional Infrared Baby Adult Digital Thermometer

    Professional Infrared Baby Adult Digital Thermometer
    CONTACT US
    Professional Infrared Baby Adult Digital Thermometer

      Professional Infrared Baby Adult Digital Thermometer

    Features


     Instant reading; Quick measurement, get reading in 1 second.
     Adopt the latest algorithm with optimized temperature calibration function.

     Accurate and reliable; ±0.2ºC High accuracy.

     Smart and Intelligent; One-button easy operation.
     Tri-color indicator light, display green, orange & red with fever alarm function.
     Memory function; Memory recall of 35 reading.
     Multi function design, can measure forehead/ear, room, object temperature.
     Switching between mute and un-mute.
     Switching between Fahrenheit and Celsius.
     Automatic shutdown and power saving.
     Optional function: 1. Ear probe cover.  2. Bluetooth connection.
    Specifications

     
    Model No. FC-IR100
    Measurement range Ear & Forehead: 32.0°C-42.9°C (89.6°F-109.2°F)
    Object: 0°C-100°C (32°F-212°F)
    Measuring accuracy Ear & Forehead mode:±0.2ºC /±0.4°F
    Object mode:±1.0°C/1.8°F
    Display  LCD backlight
    Automatic shutdown 10s±1s
    Memory Memory 35 groups of measured temperature.
    Fever alarm Low fever:37.4ºC<=T<=37.9ºC°(99.3°F-100.3°F)
    High fever:38ºC<=T<=42.9ºC(100.4°F-109.2°F)
    Operational conditions Temperature: 10ºC-40ºC (50°F-104°F)
    Humidity: 15-95%RH, non-condensing

    Atmospheric pressure: 86-106 kPa
    Battery 2*AAA, can be used for more than 3000 times
    Weight 66g(without battery); 81g (with battery)
    Product Dimension 39*27.3*160mm
    Packing size 46.5*46.5*169mm
    Full set weight 113g (including products / bags / instructions/ batteries)

    4.Overview

    Infrared Thermometer measures the body temperature based on the infrared energy emitted from the eardrum or the forehead. Users can quickly get measurement results after positioning properly the temperature probe in the ear canal or forehead.

    Normal body temperature is a range. The following tables shows that this normal range also varies by site. Therefore, readings from different site should not be directly compared. Tell your doctor what type of thermometer you used to take your temperature and on what part of the body. Also bear this in mind if you are diagnosing yourself.

     

    Measurements

    Forehead temperature

    36.1°C to 37.5°C (97°F to 99.5°F)

    Ear temperature

    35.8°C to 38°C (96.4°F to 100.4°F)

    Oral temperature

    35.5°C to 37.5°C (95.9°F to 99.5°F)

    Rectal temperature

    36.6°C to 38°C (97.9°F to 100.4°F)

    Axillary temperature

    34.7°C-37.3°C (94.5°F-99.1°F)

     

    5.Structure

    The thermometer consists of a shell, an LCD, a measure button, a beeper, an infrared temperature sensor, and a Microprocessor.

    6.Operating principle

    The infrared temperature sensor collects infrared energy emitted by the eardrum or the skin surface. After being focused by a lens, the energy is converted into a temperature reading by the thermopiles and measurement circuits.

    7.Indications for use

    The Dual-mode Infrared Thermometer is intended for the measurement of human body temperatures. The forehead mode is indicated for people of all ages and the eardrum mode is indicated for people above three months old.

    8.Contraindications

    Do not use the thermometer if the ear is infected with otitis or suppuration.

    9.Temperature taking tips

    1) It is important to know each individual's normal temperature when they are well. This is the only way to accurately diagnose a fever. Record readings twice a day (early morning and late afternoon). Take the average of the two temperatures to calculate normal oral equivalent temperature. Always take the temperature in the same location, since the temperature readings may vary from different locations on the forehead.

    2) A child's normal temperature can be as high as 99.9°F (37.7) or as low as 97.0°F (36.11). Please note that this unit reads 0.5ºC (0.9°F) lower than a rectal digital thermometer.

    3) External factors may influence ear temperatures, including when an individual has:

    • been lying on one ear or the other

    • had their ears covered

    • been exposed to very hot or very cold temperatures

    • been recently swimming or bathing

    In these cases, remove the individual from the situation and wait 20 minutes prior to taking a temperature.

    Use the untreated ear if prescription ear drops or other ear medications have been placed in the ear canal.

    4) Holding the thermometer for too long in the hand before taking a measurement can cause the device to warm up. This means the measurement could be incorrect.

    5) Patients and the thermometer should stay in steady-state room condition for at least 30 minutes.

    6) Before placing the thermometer sensor onto the forehead, remove dirt, hair, or sweat from the forehead area. Wait 10 minutes after cleaning before taking measurement.

    7) Use an alcohol swab to carefully clean the sensor and wait for 5 minutes before taking a measurement on another patient. Wiping the forehead with a warm or cool cloth may impact your reading. It is advised to wait 10 minutes before taking a reading.

    8) In the following situations it is recommended that 3-5 temperatures in the same location be taken and the highest one taken as the reading:

    • Newborn infants in the first 100 days.

    • Children under three years of age with a compromised immune system and for whom the presence or absence of fever is critical.

    • When the user is learning how to use the thermometer for the first time until he/she has familiarized himself/herself with the instrument and obtains consistent readings.

    10.Care and cleaning

    Use an alcohol swab or cotton swab moistened with 70% alcohol to clean the thermometer casing and the measuring probe. After the alcohol has completely dried out, you can take a new measurement.

    Ensure that no liquid enters the interior of the thermometer. Never use abrasive cleaning agents, thinners or benzene for cleaning and never immerse the instrument in water or other cleaning liquids. Take care not to scratch the surface of the LCD screen.

    11.Warranty and After-Sale Service

    The device is under warranty for 12 months from the date of purchase.

    The batteries, the packaging, and any damage caused by improper use are not covered by the warranty.

    Excluding the following user-caused failures:

    • Failure resulting from unauthorized disassembly and modification.

    • Failure resulting from an unexpected dropping during application or transportation.

    • Failure resulting from not following the instructions in the operating manual.

    OUR FACTORY
    Professional Infrared Baby Adult Digital Thermometer

    Performance show

    Professional Infrared Baby Adult Digital Thermometer

    Professional Infrared Baby Adult Digital Thermometer
    CONTACT US
    Professional Infrared Baby Adult Digital Thermometer

     

    Sheet Metal Fabrication

    Sheet Metal Fabrication,Ss Steel Plate,Metal Chequered Plate,Patterned Plate Sheet Metal

    Suzhou Gold ant Precision Sheet Metal Co.,Ltd , https://www.sgpsheetmetal.com

    Previous Post: 15000lbs 12V 4X4 Recovery Electric Winch with Synthetic Rope
    Next Post: Anhui's Instrument and Instrument Export Increased 115.5% YoY in the First Quarter
    Home
    Recent Posts
    • 15000lbs 12V 4X4 Recovery Electric Winch with Sy…
    • Professional Infrared Baby Adult Digital Thermom…
    • Anhui's Instrument and Instrument Export Inc…
    • Outstanding Appearance 14 Seater Passenger Trans…
    • Domestic heavy-duty truck market growth in 2011
    • Weichai has strong production and sales in 2011,…
    • Increased demand for imported cars will increase…
    • New standard for valve electric devices implemen…
    • Supreme Law: Not all drunk driving is a criminal…
    • 开采倾斜、急倾斜矿体时采区如何划
    • Ship giant layout of offshore equipment behind t…
    • Why the United States misunderstands why Toyota …
    • BorgWarner Exhaust Gas Recirculation Valve Batch…
    • Baby Care LCD Digital Outdoor Indoor Electronic …
    • Customized ABS Parts for Auto Plastic Parts
    • Chrysler Global Automotive Sales Increase 20% in…
    • Rank of China's Complete Listed Companies in…
    • Research on Process Calculation of Compressor Co…
    • Reconstruction of chiller in central air conditi…
    • Jiangsu Changzhou Institute of Metrology Technol…